Hello, welcome to Anlai Industrial Equipment Technology Co.,Ltd!

v-cell-filter
  • best Tank seal HEPA Filter Box for clean room ceiling suppliers
    Tank seal HEPA Filter Box for clean room ceiling

    Tank seal HEPA Filter Box for clean room ceiling

  • best Nylon Mesh Pre-filter suppliers
    Nylon Mesh Pre-filter

    Nylon Mesh Pre-filter

  • best H14 HEPA filter FFUs cleanroom ceiling DC FFU Fan filter Unit suppliers
    H14 HEPA filter FFUs cleanroom ceiling DC FFU Fan filter Unit

    FFU fan filter unit is type of unit used for filtering laminar air and supplying clean air. FFU can be used stand alone or installed modularly. FFU is the core when making clean room equipment for a given space including clean booth, clean bench and clean room assembly.

     

    Technical Parameters: 

     

    Model

    FFU-2*2

    FFU-2*4

    FFU-3*4

    FFU-4*4

    Overall size

     W * L * H (mm)

    575 * 575 * 300

    575 * 1175 * 300

    875 * 1175 * 300

    1175 * 1175 * 380

    HEPA filter size  

    W * L * H (mm)

    570 * 570 * 69

    570 * 1170 * 69

    870 * 1170 * 69

    1170 * 1170 * 69

    Efficiency

    HEPA 0.3μm@≥99.99% OR ULPA 0.12@≥99.9995%

    Prefilter (optional)

    Washable non-woven fabric

    Construction

    Electro galvanized metal sheet OR stainless steel or high quality aluminum sheet

    Air velocity (m/s)

    0.35~0.45

    0.35~0.45

    0.35~0.45

    0.35~0.45

    Air flow (CMH)

    410~513

    840~1080

    1290~1650

    1720~2160

    Speed control

    3 modes, 5 modes, or induction control

    Noise (dB)

    48 ~ 50

    48 ~ 52

    50 ~ 56

    52 ~ 58

    Consumption

    AC

    ≤ 98

    ≤ 150

    ≤ 180

    ≤200

    DC

    ≤ 65

    ≤ 90

    ≤ 130

    ≤160

    Power

    AC single phase 110/220V OR three phase 220/380V 50/60Hz Or DC 220V

    Overload protection

    Included (terminals or quick coupling are optional)

    Weight (KG)

    28

    40

    47

    55

     

     

     

    Features:

    The master switch inner set with insurance and indicator light

    The control mode is flexible, can be three or five air velocity speed adjustment

    Abnormal indicator light to understand the operation state of the equipment

     

     

    Options available:

    1. ULPA filter (99.9995 @0.1μm)
    2. stainless steel or AL case
    3. super thin design
    4. other requirements

    001FFU-EN.jpg002ffu-EN.jpg

     

     

    advantage of FFUs.jpg

     

    Our Services

     Factory testing (all the sets you ordered):  

    All of equipment is individually factory tested for safety and performance in accordance with international Standards. Each unit is shipped with a documentation outlining the tests undertaken and the unit’s individual results for each unit.

    Factory test include:

    --appearance testing

    --functional test and visual inspection

    --electrical safety tests

    --air velocity testing

    --noise testing

     

    Warranty:

    Our equipment is warranty for 1 year excluding consumable parts and accessories.

    All equipment is shipped with a comprehensive use’s manual complete with a report documenting all test procedures.

    Additional IO/OQ/GMP document is available upon request.

    Contact our sales representative for specific warranty details or document request. 

     

    Vertical inflow Hardwall Modular cleanroom

    QQ20141104141353.jpg

     

    Packaging & Shipping

     Vertical inflow Hardwall Modular cleanroom

    Company Information

     Own factory with competitive price

    Automatic production line.

    Nearly 20 years experience in cleanroom industry.

    We are an expert in providing customized solutions.

    Timely delivery with perfect quality.

    Fortune 500 companies’ choice.

    Have passed ISO9001.2008 certification.

    #010.png20150213123836193619.jpg

     

     

      FFU fan filter unit 

     

     

  • best Factory price hepa filter fan motorized cleanroom fan filter unit ffu suppliers
    Factory price hepa filter fan motorized cleanroom fan filter unit ffu

    FFU fan filter unit is type of unit used for filtering laminar air and supplying clean air. FFU can be used stand alone or installed modularly. FFU is the core when making clean room equipment for a given space including clean booth, clean bench and clean room assembly.

     

    Technical Parameters: 

     

    Model

    FFU-2*2

    FFU-2*4

    FFU-3*4

    FFU-4*4

    Overall size

     W * L * H (mm)

    575 * 575 * 300

    575 * 1175 * 300

    875 * 1175 * 300

    1175 * 1175 * 380

    HEPA filter size  

    W * L * H (mm)

    570 * 570 * 69

    570 * 1170 * 69

    870 * 1170 * 69

    1170 * 1170 * 69

    Efficiency

    HEPA 0.3μm@≥99.99% OR ULPA 0.12@≥99.9995%

    Prefilter (optional)

    Washable non-woven fabric

    Construction

    Electro galvanized metal sheet OR stainless steel or high quality aluminum sheet

    Air velocity (m/s)

    0.35~0.45

    0.35~0.45

    0.35~0.45

    0.35~0.45

    Air flow (CMH)

    410~513

    840~1080

    1290~1650

    1720~2160

    Speed control

    3 modes, 5 modes, or induction control

    Noise (dB)

    48 ~ 50

    48 ~ 52

    50 ~ 56

    52 ~ 58

    Consumption

    AC

    ≤ 98

    ≤ 150

    ≤ 180

    ≤200

    DC

    ≤ 65

    ≤ 90

    ≤ 130

    ≤160

    Power

    AC single phase 110/220V OR three phase 220/380V 50/60Hz Or DC 220V

    Overload protection

    Included (terminals or quick coupling are optional)

    Weight (KG)

    28

    40

    47

    55

     

     

     

    Features:

    The master switch inner set with insurance and indicator light

    The control mode is flexible, can be three or five air velocity speed adjustment

    Abnormal indicator light to understand the operation state of the equipment

     

     

    Options available:

    1. ULPA filter (99.9995 @0.1μm)
    2. stainless steel or AL case
    3. super thin design
    4. other requirements

    001FFU-EN.jpg002ffu-EN.jpg

     

     

    advantage of FFUs.jpg

     

    Our Services

     Factory testing (all the sets you ordered):  

    All of equipment is individually factory tested for safety and performance in accordance with international Standards. Each unit is shipped with a documentation outlining the tests undertaken and the unit’s individual results for each unit.

    Factory test include:

    --appearance testing

    --functional test and visual inspection

    --electrical safety tests

    --air velocity testing

    --noise testing

     

    Warranty:

    Our equipment is warranty for 1 year excluding consumable parts and accessories.

    All equipment is shipped with a comprehensive use’s manual complete with a report documenting all test procedures.

    Additional IO/OQ/GMP document is available upon request.

    Contact our sales representative for specific warranty details or document request. 

     

    Vertical inflow Hardwall Modular cleanroom

    QQ20141104141353.jpg

     

    Packaging & Shipping

     Vertical inflow Hardwall Modular cleanroom

    Company Information

     Own factory with competitive price

    Automatic production line.

    Nearly 20 years experience in cleanroom industry.

    We are an expert in providing customized solutions.

    Timely delivery with perfect quality.

    Fortune 500 companies’ choice.

    Have passed ISO9001.2008 certification.

    #010.png20150213123836193619.jpg

     

     

      FFU fan filter unit 

     

     

  • best The HEPA filter Box suppliers
    The HEPA filter Box

    HEPA filter Box

     

    Illustration:

    1. Diffuser plate

    2. Countersunk head screws

    3. Flange

    4. Cabinet

    5. Hex head screws

    6. Flat washers

    7. HEPA filter

    8. Hex bolts

    Main Technology Parameter:

    Model

    Rated Airflow
    (m3/h)

    HEPA Filter
    (WXHXD)mm

    Cabinet Size
    (W×L×H)mm

    Flange Size

    Ceiling Hole Size

    HEPA Type

    Tube at Top

    Tue at Side

    (A×B)mm

    (W×L)mm

    AL-320T/1

    AL-320S/1

    500

    320×320×96

    370×370×380

    200×200

    380×380

    Mini-pleated HEPA

    AL-320T/2

    AL-320S/2

    320×320×220

    370×370×500

    HEPA with Clapboard

    AL-484T/1

    AL-484S/1

    1000

    484×484×96

    534×534×380

    320×200

    544×544

    Mini-pleated HEPA

    AL-484T/2

    AL-484S/2

    484×484×220

    534×534×500

    HEPA with Clapboard

    AL-610T/1

    AL-610S/1

    1500

    610×610×96

    660×660×380

    400×200

    670×670

    Mini-pleated HEPA

    AL-610T/2

    AL-610S/2

    610×610×220

    660×660×500

    HEPA with Clapboard

    AL-915T/1

    AL-915S/1

    2000

    915×610×96

    965×660×380

    500×200

    975×670

    Mini-pleated HEPA

    AL-915T/2

    AL-915S/2

    915×610×220

    965×660×500

    HEPA with Clapboard

    AL-1220T/1

    AL-1220S/1

    3000

    1220×610×96

    1270×660×380

    500×300

    1280×670

    Mini-pleated HEPA

    AL-1220T/2

    AL-1220S/2

    1220×610×220

    1270×660×500

    HEPA with Clapboard

     

    Note: 1. Please indicate if HEPA cabinets inside with insulation

    2. Please indicate if required airflow control valve

    3. Customized design is welcome.

     

     

  • best G4 panel pleated prefilter suppliers
    G4 panel pleated prefilter

    G4 panel pleated prefilter

     

     

    Product Introduction:

    Standard pleated primary filter, gradient-type structure to provide maximum airflow filter area, which is five times of the plane-type filter, welded steel protect net using surface rust treatment, can be well fixed linear pleated structure, protect filter media not punctured and prevent media not deformed due to excessive pressure, to ensure that filter surface is fully utilized. Can be common or moisture-proof paper frame, recycled or incinerated after use, non-pollution, environmental compliance.

     

    Features:

    Large filter area

    long using life

    large air volume

    low resistance

    large dust holding capacity

     

     

    ApplicationsAir conditioning systems primary filtration, the Pre-filter in multi-stage filtration system 

     

    Material and operation conditions:

    Media

    Synthetic fiber

    Sealant

    Adhesive

    Frame

    Aluminum/Galvanized steel/Stainless steel/ Cardboard

    Protect Net

    Galvanized steel/Aluminum/Stainless steel/

    Filter Efficiency

    (EN779)

    G1:40%@2.0μm; G2:65%@2.0μm;

    G3:85%@2.0μm; G4:90%@2.0μm.

    Max. Temperature

    80℃

    Max. Humidity

    100%

     

    Dimension & Parameters:

     

    Model

    Size

    (W×H×D)mm

    Air flow

    (m³/h)

    Intital Resistance

    (pa)

    Final Resistance

    (pa)

    Media area

    (m2)

    Dust Holding

    (g)

    Efficiency

    AL-P1-001

    287×592×46

    1400

    ≤25

    100-200

    1.23

    60

    G1

    AL-P1-002

    287×592×46

    1400

    ≤30

    100-200

    1.23

    70

    G2

    AL-P1-003

    287×592×46

    1400

    ≤40

    100-200

    1.23

    80

    G3

    AL-P1-004

    287×592×46

    1400

    ≤45

    150-250

    1.23

    100

    G4

    AL-P1-005

    592×592×46

    2800

    ≤25

    100-200

    1.23

    104

    G1

    AL-P1-006

    592×592×46

    2800

    ≤30

    100-200

    1.23

    104

    G2

    AL-P1-007

    592×592×46

    2800

    ≤40

    100-200

    1.23

    117

    G3

    AL-P1-008

    592×592×46

    2800

    ≤45

    150-250

    1.23

    222

    G4

     

    Customized design is welcome.









  • best Activate Carbon Filter suppliers
    Activate Carbon Filter

    Activate Carbon Filter

     

     Material and operation conditions

    Media

    Activated carbon fiber

    Sealant

    Adhesive

    Frame

    Aluminum/Galvanized steel/Stainless steel/Cardboard

    Odor removal rate

    >70%

    Max. Temperature

    80℃

    Max. Humidity

    100%

    Product Introduction <<<

    Activated carbon filters are pleated type pre-filter, frame choose moisture-proof and humidity resistant industrial cardboard or aluminum frame , protect net surface with rust treatment , can be well fixed linear pleated structure. Activated carbon filter made of high quality carbon fiber media, have good effect of odor removal.

    Features: Light weight, strong ventilation, large filter area, strong adsorption performance characteristics, for low concentrations organic pollutants have a strong odor removal.

    Applications: Air conditioning and ventilation systems odor and air pollution treatment, absorption and removal of harmful gases (such as benzene, formaldehyde, ammonia, etc.), solvent recovery.

     

    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    Air flow

    (m³/h)

    Intital Resistance

    (pa)

    Media area

    (m2)

    Odor removal rate

    AL-P2-001

    287×592×21

    600

    40

    0.47

    ≥70%

    AL-P2-002

    490×592×21

    1000

    40

    0.77

    ≥70%

    AL-P2-003

    592×592×21

    1150

    40

    0.93

    ≥70%

    AL-P2-004

    287×592×46

    650

    40

    0.52

    ≥70%

    AL-P2-005

    490×592×46

    1100

    40

    0.86

    ≥70%

    AL-P2-006

    592×592×46

    1250

    40

    0.97

    ≥70%

    AL-P2-004

    287×592×50

    700

    40

    0.56

    ≥70%

    AL-P2-005

    490×592×50

    1150

    40

    0.93

    ≥70%

    AL-P2-006

    592×592×50

    1350

    40

    1.06

    ≥70%

     

    Customized design is welcome.

     


     




  • best G3 Pleated Primary Filter suppliers
    G3 Pleated Primary Filter

     G3 Pleated Primary Filter 


    Material and operation conditions

     

    Media

    Synthetic fiber

    Sealant

    Adhesive

    Frame

    Aluminum/Galvanized steel/Stainless steel/ Cardboard

    Protect Net

    Galvanized steel/Aluminum/Stainless steel/

    Filter Efficiency

    (EN779)

    G1:40%@2.0μm; G2:65%@2.0μm;

    G3:85%@2.0μm; G4:90%@2.0μm.

    Max. Temperature

    80℃

    Max. Humidity

    100%

    Product Introduction<<<

    Standard pleated primary filter, gradient-type structure to provide maximum airflow filter area, which is five times of the plane-type filter, welded steel protect net using surface rust treatment, can be well fixed linear pleated structure, protect filter media not punctured and prevent media not deformed due to excessive pressure, to ensure that filter surface is fully utilized. Can be common or moisture-proof paper frame, recycled or incinerated after use, non-pollution, environmental compliance.


    Features: Large filter area, long using life, large air volume, low resistance and dust holding capacity


    Applications: Air conditioning systems primary filtration, the Pre-filter in multi-stage filtration system 

     

     

    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    Air flow

    (m³/h)

    Intital Resistance

    (pa)

    Final Resistance

    (pa)

    Media area

    (m2)

    Dust Holding

    (g)

    Efficiency

    AL-P1-001

    287×592×46

    1400

    25

    100-200

    1.23

    60

    G1

    AL-P1-002

    287×592×46

    1400

    30

    100-200

    1.23

    70

    G2

    AL-P1-003

    287×592×46

    1400

    40

    100-200

    1.23

    80

    G3

    AL-P1-004

    287×592×46

    1400

    45

    150-250

    1.23

    100

    G4

    AL-P1-005

    592×592×46

    2800

    25

    100-200

    1.23

    104

    G1

    AL-P1-006

    592×592×46

    2800

    30

    100-200

    1.23

    104

    G2

    AL-P1-007

    592×592×46

    2800

    40

    100-200

    1.23

    117

    G3

    AL-P1-008

    592×592×46

    2800

    45

    150-250

    1.23

    222

    G4

    Customized design is welcome.

     






  • best G3 Pleated Primary Air Filter With Paper Frame suppliers
    G3 Pleated Primary Air Filter With Paper Frame

     G3 Pleated Primary Filter 


    Material and operation conditions

     

    Media

    Synthetic fiber

    Sealant

    Adhesive

    Frame

    Aluminum/Galvanized steel/Stainless steel/ Cardboard

    Protect Net

    Galvanized steel/Aluminum/Stainless steel/

    Filter Efficiency

    (EN779)

    G1:40%@2.0μm; G2:65%@2.0μm;

    G3:85%@2.0μm; G4:90%@2.0μm.

    Max. Temperature

    80℃

    Max. Humidity

    100%

    Product Introduction<<<

    Standard pleated primary filter, gradient-type structure to provide maximum airflow filter area, which is five times of the plane-type filter, welded steel protect net using surface rust treatment, can be well fixed linear pleated structure, protect filter media not punctured and prevent media not deformed due to excessive pressure, to ensure that filter surface is fully utilized. Can be common or moisture-proof paper frame, recycled or incinerated after use, non-pollution, environmental compliance.


    Features: Large filter area, long using life, large air volume, low resistance and dust holding capacity


    Applications: Air conditioning systems primary filtration, the Pre-filter in multi-stage filtration system 

     

     

    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    Air flow

    (m³/h)

    Intital Resistance

    (pa)

    Final Resistance

    (pa)

    Media area

    (m2)

    Dust Holding

    (g)

    Efficiency

    AL-P1-001

    287×592×46

    1400

    25

    100-200

    1.23

    60

    G1

    AL-P1-002

    287×592×46

    1400

    30

    100-200

    1.23

    70

    G2

    AL-P1-003

    287×592×46

    1400

    40

    100-200

    1.23

    80

    G3

    AL-P1-004

    287×592×46

    1400

    45

    150-250

    1.23

    100

    G4

    AL-P1-005

    592×592×46

    2800

    25

    100-200

    1.23

    104

    G1

    AL-P1-006

    592×592×46

    2800

    30

    100-200

    1.23

    104

    G2

    AL-P1-007

    592×592×46

    2800

    40

    100-200

    1.23

    117

    G3

    AL-P1-008

    592×592×46

    2800

    45

    150-250

    1.23

    222

    G4

    Customized design is welcome.

     






  • best V cell compact medium air filter suppliers
    V cell compact medium air filter

    V-type Medium filter                                     

    Material and Operation Conditions

    Media

    High humidity-resistance Glass fiber

    Sealant

    PU Polyurethane Adhesive

    Frame

    Plastic/Aluminum/Galvanized plate/Stainless steel

    Separator

    EVA  hot melt

    Gasket

    EVA  Neoprene

    Filter Efficiency

     (EN779)

    F6:65%@0.5μm; F7:85%@0.5μm;

    F8:90%@0.5μm; F9:95%@0.5um

    Max. Temperature

    70

    Max. Humidity

    80%-100%

      

    Product Introduction <<<

    V-type air filter is mainly used for filtration of more than 0.5μm dust particles, multi- V Mini-pleat design with large filtration area, low resistance, long service life, the use of waterproof ultra-fine glass fiber media, polypropylene plastic frame can be completely incinerated, and mounting flange frame is interchangeable with bag filter.


    Features: Air-conditioning system secondary filtration, achieve big air flow demand at low wind resistance.


    Application: Industrial and commercial ventilation systems, centralized ventilation and air conditioning system of clean room

     

    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    No. of

    packs

    Air flow

    (m³/h)

    Intital Resistance

    (pa)

    Final

    Resistance

    (pa)

    Media area

    (m2)

    Dust Holding

    (g)

    Efficiency

    AL-MV-001

    592×592×292

    3

    2800

    ≤80

    300-400

    16.2

    1460

    F7

    AL-MV-002

    592×592×2 92

    4

    3700

    ≤80

    300-400

    21.6

    1950

    F7

    AL-MV-003

    610×610×292

    5

    4700

    ≤80

    300-400

    27.7

    2490

    F7

    AL-MV-004

    592×592×292

    3

    2600

    ≤100

    300-400

    16.2

    1430

    F8

    AL-MV-005

    592×592×292

    4

    3500

    ≤100

    300-400

    21.6

    1900

    F8

    AL- MV-006

    610×610×292

    5

    4500

    ≤100

    300-400

    27.7

    2440

    F8

    AL-MV-007

    592×592×292

    3

    2900

    120

    400-500

    17.8

    1570

    F9

    AL-MV-008

    592×592×292

    4

    3600

    120

    400-500

    23.8

    2090

    F9

    AL-MV-009

    610×610×292

    5

    4900

    120

    400-500

    30.4

    2680

    F9

    Customized design is welcome.


     











  • best Mini pleated HEPA filter suppliers
    Mini pleated HEPA filter

    Mini-Pleated HEPA filter

    Product Introduction<<<

    Mini-pleated HEPA filter made of ultra-fine glass fiber; with hot melt adhesive separated, plastic glue can be sure that the folds spacing, to ensure the best airflow through to reach a high dust holding capacity, full use of the filter media. Double-side spray mesh grille protect net to protect filter media not damaged, special sealant ensure the tightness of the entire filter. Frame uses hard anodized to increase the degree of corrosion resistance and durability. Each filter has been strictly tested before factory.

    Features: High efficiency, low resistance, light weight, thin, easy installation, low running costs.

    Application: Electronics, medicine, food, semiconductor manufacturing, Atomic, precision machinery, cosmetics and other places required high clean class.


    Material and Operation Conditions:

    Media

    Glass fiber

    Sealant

    PU Polyurethane

    Frame

    Aluminum/Galvanized steel/Stainless steel

    Protect net

    Spray diamond mesh

    Separator

    EVA hot melt adhesive

    Gasket

    PU Polyurethane, EVA, Neoprene

    Filter Efficiency

    (EN1822)

    H13: 99.97-99.99%@0.3μm

    H14: 99.995-99.999%@0.3μm

    Max. Temperature

    70

    Max. Humidity

    80%




    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    Air flow(m³/h)

    Intital Resistance(pa)

    Final Resistance(pa)

    Media

    area (m2)

    Dust Holding(g)

    Efficiency

    AL-H2-001

    305×305×69

    260

    ≤200

    400-600

    2.5

    150

    H13-H14

    AL-H2-002

    484×484×69

    700

    ≤200

    400-600

    6.6

    400

    H13-H14

    AL-H2-003

    610×610×69

    1000

    ≤200

    400-600

    10.7

    650

    H13-H14

    AL-H2-004

    610×915×69

    1600

    ≤200

    400-600

    16.0

    950

    H13-H14

    AL-H2-005

    1220×610×69

    2100

    ≤200

    400-600

    21.3

    1000

    H13-H14

    AL-H2-006

    484×484×96

    1000

    ≤200

    400-600

    10.2

    620

    H13-H14

    AL-H2-007

    610×610×96

    1500

    ≤200

    400-600

    16.2

    980

    H13-H14

    AL-H2-008

    1220×610×96

    3100

    ≤200

    400-600

    31.9

    1920

    H13-H14

    Customized design is welcome.





  • best 280℃ high temperature HEPA air filter suppliers
    280℃ high temperature HEPA air filter

     High Heat resistance HEPA Filter with Clapboard

    Material and Operation Conditions

    Media

    Micron Glass fiber

    Sealant

    Red silicon for 250-280

    Ceramic glue for 350-400

    Frame

    <250 Aluminum/Galvanized steel/Stainless steel

    >250Galvanized steel or Stainless steel

    Separator

    0.035mm thick aluminum oil

    Gasket

    Silica Gel Plate: 250-280

    Polytetrafluoetylene :350-400

    Filter Efficiency

    (EN1822)

    H13: 99.97-99.99%@0.3μm

    H14: 99.995-99.999%@0.3μm

    Max. Temperature

    250-280              350-400

    Max. Humidity

    80%


    Product Introduction<<<

    Ultra-fine glass fiber media, aluminum foil separator, stainless steel frame, assembled from a special high temperature-resistance sealant can use well under high temperature environment at 400 , the frame material and thickness to provide a variety options of the frame material and thickness. Each filter has been strictly tested before factory.

    Features: High efficiency, low resistance, high temperature-resistance, long-term use at 400  environment.

    Application: Electronics, semiconductor, pharmaceutical, food and other which production processes requires

     a clean oven or high temperature air purification equipment and systems.

    Dimension and Parameter:



    Dimension & Parameters<<<

    Model

    Size

    (W×H×D)mm

    Air flow(m³/h)

    Intital Resistance(pa)

    Final Resistance(pa)

    Media

    area (m2)

    Dust Holding(g)

    Efficiency

    AL-H3-001

    484×480×120

    390

    ≤200

    400-600

    4.4

    230

    H13-H14

    AL-H3-002

    610×610×120

    620

    ≤200

    400-600

    7.1

    370

    H13-H14

    AL-H3-003

    1220×610×120

    1500

    ≤200

    400-600

    14.1

    740

    H13-H14

    AL-H3-004

    484×480×150

    530

    ≤200

    400-600

    6.0

    320

    H13-H14

    AL-H3-005

    610×610×150

    1000

    ≤200

    400-600

    9.7

    510

    H13-H14

    AL-H3-006

    1220×610×150

    2000

    ≤200

    400-600

    19.3

    1020

    H13-H14

    AL-H3-007

    484×480×220

    1000

    ≤200

    400-600

    9.8

    600

    H13-H14

    AL-H3-008

    610×610×220

    1600

    ≤200

    400-600

    15.8

    920

    H13-H14

    AL-H3-009

    1220×610×220

    3000

    ≤200

    400-600

    31.6

    1750

    H13-H14

    Customized design is welcome.